METHANE TESTING DTLA

Methane Testing Success on Building Renovation to Help House Homeless in DTLA

Terra-Petra provided methane testing services for an existing 3-story, slab-on-grade building located at 601 East 5th Street in Los Angeles, CA. The 16,500 SF 1922 building is being renovated as a homeless shelter. 

The building site is located within a City of Los Angeles Methane Buffer Zone. The methane soil gas investigation complied with LADBS Information Bulletin Ref. No. 91.7104.1, P/BC 2002-101, was performed under Terra-Petra’s LADBS Methane Testing Lab License #10224.

METHANE TESTING DTLA

Overcoming Methane Testing Difficulties

Terra-Petra has encountered a few difficulties performing work within existing buildings. One such difficulty is limited accessibility.Standard truck-mounted drill rigs can’t access the inside of a building if there’s not enough head clearance (ceilings lower than the top of the drill) or a limit on door opening size. 

Drilling equipment must fit through the front door, be lower than the ceiling, and be light enough to be handled by personnel or pushed on a hand cart.

Once inside the building, underground utilities may be challenging to locate, as DigAlert only identifies exterior utility lines. As-built plans are always essential when working indoors. If these plans aren’t available, utility clearance equipment may be employed.

About Core Cutting

Another difficulty is the existing concrete slab. Most direct push equipment can punch through existing concrete slabs, but leaves a less-than-optimal hole that needs to be repaired after use. Core cutting through the slab is another option that allows a clean cut through the slab and is easy to repair. 

Core cutting also adds time and costs to the project. But, if a slab is post-tensioned, it is imperative that the cables are located prior to entering the slab, since hitting a cable could damage the structural integrity of the slab.  

Methane Testing Downtown Los Angeles

These are just some issues associated with completing a methane investigation inside an existing building. Terra-Petra is, however, always well-equipped to get the job done, no matter the situation. And the success of the 601 East 5th Street building inspection has proved that to be true. We are proud to contribute to the Los Angeles City Center Redevelopment Plan.

Learn more about Terra-Petra’s methane testing and inspection services.

Methane Mitigation Services – Harbor City, CA

Terra-Petra is currently working with a Victorville design team to provide  Soil Gas Investigation (SGI), methane mitigation design, inspection, and consulting services for a retail development located in Harbor City, CA. The project will consist of a new 3-story cannabis facility (occupied by a dispensary, cultivation rooms, manufacturing facility and distribution ) constructed out of steel frame, with insulated metal panel exterior and interior walls, and an open air parking garage below the structure. The total building footprint is approximately 4,712 SF and total site square footage is 41,894.20 SF.

Terra-Petra will be consulting on all mitigation matters relative to the site, including methane testing, laboratory testing, methane mitigation system design, construction administration support, and DMBI inspections to be in compliance with City of Los Angeles Department of Building and Safety (LADBS) codes.

Methane Mitigation Design – Torat Hiyam

Level II Methane Mitigation Design

Terra-Petra has just closed  with Torat Hiyam to provide methane mitigation design for their new project in Los Angeles, CA.

The new construction will consist of a 5 story school building, with a basketball court and a library.

The scope of work will include a Level II methane mitigation design plan with permitting to be approved by LADBS Mechanical Department Plan Check.

Methane Soil Gas Investigation In Los Angeles

Terra-Petra has submitted a bid to Data Specialties to conduct a methane soil gas investigation on a LADBS Methane Buffer Zone Property on in Los Angeles, CA.  The proposed project will consist of an electrical upgrade, with no new building construction.

The scope of work includes shallow and deep boring at the site, and monitoring methane gas concentrations and pressure on consecutive days in order to prepare an LADBS Certificate of Compliance for Methane Test Data.

purple line extension project

Methane Monitoring – LA Metro Purple Line Extension Project

Methane Monitoring Reports For Metro Purple Line Expansion Project

Terra-Petra is pleased to announce that our Environmental Engineering Specialist has signed off on monthly methane monitoring reports required for the Metro Purple Line Extension project in Beverly Hills.

The soil gas monitoring will be done at two zones: the Beverly Hills High School (BHHS) area, and near the Fine Arts Theater on Wilshire Blvd.

City of Los Angeles Methane Mitigation and Gas Detection System Design

Methane Mitigation Design

Methane Mitigation And Gas Detection System Design, City of Los Angeles

Terra-Petra wrapped up a City of Los Angeles Methane Mitigation and Gas Detection System Design for a Level 5 methane site for Welcome Projects of Los Angeles, CA. Terra-Petra provided design consultation for the new ground up single-family Accessory Dwelling Unit (ADU) as well as the addition to the existing home.